Direct Current Solar Ready Air Conditioning

 Securus News

 

 

 

9/6/2011  Direct current, solar air conditioning systems are now available from 3600 BTU to 18000 BTU and can operate day and night directly from wind, solar PV and hydro with a battery bank. The 100% DC cooling systems range from a quarter to 1.5 Ton and are effective up to 800 square feet. All of the sustainable AC systems are powered by any renewable energy source are ideal for cooling electronics, off-grid applications, high energy cost environments and add-on/augmentation. Renewable climate control is the best way to ensure sustainable, safe comfort for the entire planet.

 

Securus Flyer      2011 Securus Hardware      News Archive

Subscribe to Securus Newsletter

 

One reason that the 48 volt air conditioner makes the best use of solar power is because there are no losses associated with converting DC power from solar, wind and or hydro to charge the deep cell batteries that power the Securus system.  Solar Air Conditioning Is Priceless. The Securus systems save energy 24/7 and continue to run off batteries during blackouts saving loved ones, pets, electronics and valuables.

 

 Securus Direct Current System

 

 

The 1.5 ton heat pump circuit connection is 48 VDC at 32 amps maximum power draw.  Non-ozone depleting 410A is the refrigerant for the ductless split with a single remote controlled air handler set up to receive 48 VDC through the outside compressor/condenser cabinet circuit.

 

Max Cooling............................................ 18,000 BTU
SEER........................................................ 20 (estimate)
Voltage...................................................... 48 VDC (44-52 v)
Refrigerant............................................... R-410a
Compressor Motor................................. Brushless DC Rotary Vane
Maximum Power Consumption.............. 1500 watts
 
Features:
 

• High-SEER Brushless DC permanent magnet motor

• Rotary Compressor with high efficiency operation

• Innovative control logic matching cooling capacity to demand

• Quiet operation

• Solar panel & battery requirements are additional

• Can be Grid Tied

 

 

 Telecom Self-Contained DC 17000 T

 

The DC Comfort T Series Climate Control Unit is controlled by a thermostat that senses the internal enclosure temperature. When cooling is desired, the compressor, evaporator blower and condenser fan turn on. Cool air is discharged from the DC Comfort T Series into the enclosure.

 

Optimized battery management is included in every DC Comfort T Series system. The control board on the system monitors battery consumption and protects the  components from over temperature through a low voltage disconnect.

 

Cooling Capacity......................................... 5300 watts -  17,000 BTU
Power Consumption................................... 1400 Watts @ 100% Duty Cycle
Size (W x D x H) inches............................... 21.50" x 11.25" x 34.75"
Size (W x D x H) mm.................................... 548 x 285 x 884
Weight............................................................ 97 lbs / 44 kg
Low Voltage.................................................. 48 Volt - 43.1 volt
Restart Voltage............................................. 48 Volt - 51.5 volts
Pressure Protection.................................... High / Low
Internal Shutdown....................................... High Motor temp
Refrigerant ................................................... R134A

Manufactured................................................

USA

 

 

 Solar Dome

 

The Solar Dome is a frame-less structure consisting of aerospace composite panels. It has the strength of a standard building but the mobility of a tent. One Dome can be assembled by two people in less than four hours with nothing more than a screwdriver, wrench and step ladder. 

 

When unassembled, the enclosure can fit into the back of a pickup truck, trailer or an 8'x8'x4' container and easily transported anywhere in the world. It can be repeatedly taken down and reassembled while retaining its structural integrity.

 

14' Dome  
Diameter.......................................................... 14 ft
Height............................................................... 9 ft at center
Floor Area........................................................ 154 sq ft
Door Opening................................................. 26"x49"
Window Opening........................................... optional
Weight.............................................................. 600 lbs
   
20' Dome  
Diameter.......................................................... 20 ft
Height............................................................... 12 ft at center
Floor Area........................................................ 314 sq ft / up to 500 sq ft with loft
Door Opening................................................. 36" x 81"
Window Opening........................................... 36" x 36"
Weight.............................................................. 1,100 lbs
   
   

 

 

 

 

 

The 1.5 ton air conditioner

 saves electricity and makes

100 gallons of free hot water per day

energy star  etl logo  csa logo  ce logo

 ACWH 18000 BTU Ductless Split Heat Pump

 EnergyStar Qualified | Tax Credit Approved | 18 SEER 

 

•Standard Cooling & Heating Functions  

(W/ES, Cert Logos & hardware image)

•100 Gallons per day hot water

•Connect to any hot water tank

•Highly Efficient (S.E.E.R. 18)

•Dehumidification Function

•Circulation Function

•Digital Multifunction infrared Remote control

•Intelligent control multifunction digital dynamic

•LCD display (indoor unit)

•Defrosting function (heat pump)

•Clock Mode

•Digital 24 Hour Timer

•Sleep Mode

•Automatic 3 Dimensional Dual Louver Air Flow

•Remote Adjusted Double Louvers

•Swing Double Louver Function

•Auto Re-Start Function

•3 Fan speed Selection

•Multi-fold evaporator for faster cooling

•Quiet Operation

 

 

 
Federal & State IncentivesSolar Portal Home

info@securusair.com

 

 

The information contained herein is subject to change without notice and may not conform to local requirements.

 © Copyright 2010 SolCool One, LLC  All rights reserved.